SlideShare a Scribd company logo
1 of 28
DATA CENTER
INFRASTRUCTURE
MANAGEMENT
(DCIM)
DATA CENTER
MANAGEMENT CHALLENGES
Data
Center
Availability
Business
Efficiency
Balance the demands of availability and efficiency through out the data center lifecycle
IN AN ENVIRONMENT
OF CONSTANT CHANGE
Energy and service
cost control
Increasing availability
expectations
Regulatory
requirements
Dynamic power
variation
Uncertain
planning for
capacity or density
Cloud computing
Energy efficiency
Virtualization
Metrics and
reporting
Server
consolidation
Infrastructure
management
Data center managers need accurate and timely information to
make better decisions in real time
DCIM MARKET
DEFINITION
Data center infrastructure management
(DCIM) systems collect and manage data about a
data center’s assets, resource use and
operational status throughout the data center
lifecycle. This information is then distributed,
integrated, analyzed and applied in ways that
help managers meet business and service-
oriented goals and optimize the data center’s
performance
Physical Functional Process
• Power system
• Cooling system
• IT space
• Security
• integrations
• Monitoring and alarming
• Automation and control
• Modeling and simulation
• Software Services,
• Integrations
• Asset management
• Availability management
• Capacity management
• Change management
• Crisis management
• Financial management,
• Integrations
Level 5: Self optimizing,
autonomic
Multiple IT and infrastructure subsystems integrated; data
models used for prediction, service management, multiple
views, optimizing in near real time.
0%
DCIM MATURITY MODEL
Level 4: Optimizing
Multiple IT and infrastructure subsystems integrated; data
models used for prediction, service management, multiple
views, optimizing in near real time.
5%
Level 3: Proactive
Datacenter equipment characteristics, location and
operational status tracked. Energy and environmental data
used to reduce risks, waste.
30%
Level 2: Reactive
Software installed to monitor environment and equipment
power use. Ability to adjust cooling to demand. 80%
Level 1: Basic
No integration; basic monitoring supplied with equipment.
Health and safety. 95%
Utility
Building
Data Center Infrastructure
IT hardware
Hypervisor
Virtual Machines
Business Value
Applications
Virtualization
Management
Data Center
Infrastructure
Management
(DCIM)
DEMAND
SUPPLY
DEMAND
SUPPLY
SCHNEIDER ELECTRIC’S DCIM SOLUTIONS
A suite of modular and integrated DCIM software tools
that enable effective data center management
Resource Advisor
Data Center
Operation
Data Center Expert
Power Monitoring
Expert
Building Operation
STRUCTURE FOR DATA CENTERS
Component Benefit
Resource Advisor
Data Center
Operation
Data Center Expert
Power Monitoring
Expert
Enterprise Energy
and Sustainability
Data Center
Business Process
Data Center
Monitoring and
Control
Track and manage
enterprise energy and
carbon costs
Manage Data Center
assets, operational and
capital costs
Monitor and control
Data Center power,
cooling and security
Advanced power
monitoring, analysis
and power quality
Advanced cooling
monitoring and
automation
Building Operation
EXPECTED MARKED GROWTH (1)
“Overall, The 451 Group
believes that the DCIM
market is worth around
$240m in 2011, and will
grow to $1.2bn in 2016.”
” DATACENTER INFRASTRUCTURE
MANAGEMENT SOFTWARE”,
EXPECTED MARKED GROWTH (2)
“DCIM tools and
processes will become
mainstream in data
centers, growing from
1% penetration in
2010 to 60% in 2014.”
SCHNEIDER A LEADER IN THE
DCIM MARKET
“According to IDC analysis
and buyer perception,
Schneider Electric is an
IDC MarketScape Leader
worldwide.”
”IDC: Markets cape: Worldwide Datacenter
Infrastructure Management (DCIM)
BUSINESS BENEFITS
It is difficult to achieve the more advanced levels of datacenter
maturity, or of datacenter effectiveness generally, without extensive
use of DCIM software (451 Group, 2011)
Energy savings from well-managed data centers can reduce operating
expenses by as much as 20% (Gartner, 2010)
One integrated system bridging the gap between Facilities and IT
Plug’n’Play data center key performance indicators on web and smart
phone dashboards
Typical solution payback is less than 12 months
A new level of business intelligence for your
Data Center Infrastructure Management (DCIM).
Ability today to integrate management platforms
A vision for tomorrow for simplified, integrated management
Remove silos & create energy awareness across the entire data center
STRUCTURE WARE DATA CENTER OPERATION
PLANNING
Improve IT room allocation of
power & cooling
ANALYSIS
Leverage historical data to
improve future performance in
the data center
OPERATIONS
Rapid impact analysis in the
event of failure in the data
center
I need to know what
happens before a
failure occurs
IT Professional
Part of Structure for Data Centers
● Inventory management
● Shows device data within the physical
layout for instant access to device details
and asset attributes, and overview of data
center operations.
● Alarms within physical layout
● Provides real-time device failures within
floor layout and rack front view for live
status of data center operations
● PUE/ DCiE calculator
● Provides Power Usage Effectiveness
(PUE) or Data Center infrastructure
Efficiency (DCiE) value for information on
daily utilization of energy.
STRUCTURE WARE DATA CENTER OPERATION
● Network management
● An overview of the data center network paths
and their interconnections, provided through
guided input for reduction of human error.
● Global asset search
● Quickly locate assets through free text search
and export equipment data to excel format
● Mobile data center operations
● Integrates with Operation Mobile for access to
StruxureWare Operation on the go via the
Motorola MC75 handheld PDA.
● Live dashboard
● Gain transparency to data center key
performance indicators through easily configured
web dashboards, displaying customizable
management-level information
Asset management and documentation of data center operations
through inventory management
THE MODULAR SETUP
Structure Ware Data Center Operation forms the base layer of software, which other
modules and enhancement options can be added onto.
StruxureWare Data Center Operation
StruxureWare Data Center Expert
Structure Ware Data Center Expert is the preferred data center
monitoring platform for the solution.
Integrations
BMC Remedy
Microsoft VMM
Microsoft SCOM
Vmware vSphere
Cisco UCS
Microsoft Excel
Aperture
Schneider Electric
StruxureWare Data
Center Operation
StruxureWare Data
Center Expert
HP Openview
● IT equipment guidance
● Instant server placement recommendation
through real-time analysis of available data
center capacity.
● Virtualization capabilities
● Integrations with VMware vSphere and
Microsoft System Center Virtual Machine
Manager
● Combines information from the IT layer and
the physical infrastructure layer, enabling
data center managers to automatically
migrate their impacted virtual machines
from an impacted host server to a healthy
host server.
DATA CENTER OPERATION: CAPACITY
● Available capacity
● Global view of available capacity within an
organizational context, providing an instant
calculation of actual space, power and cooling
consumption, power and network port availability
and floor and rack weight limits against overall
data center capacity constraints.
● Business impact
● Shows the consequence of device failure on data
center infrastructure equipment for instant
identification of critical business application
impacts.
● 3D airflow analysis
● Simulate any cooling scenario in your data
center, instantly visualizing the cooling effect on
your infrastructure for easy identification of
overcooling and hotspots.
Simulation, planning, and optimization of infrastructure capacities
to right-size the data center
● Automated work order process
● Create work orders and automatically
generate tasks to move, add or change IT
and infrastructure equipment.
● Schedule, assign and track the status of
itemized tasks to implement changes in the
data center.
● New! Change management overview
● Interactive interface showing past, future
and pending changes to assist with
resource and workload balancing, avoiding
scheduling conflicts.
● New! BMC Remedy integration
● Ensure relevant information is shared and
flowing between Operation Change and the
market leading process management
system.
DATA CENTER OPERATION:
CHANGE
● New! Maintenance scheduling
● Facilitate scheduling of service and equipment
maintenance to ensure visibility to all service
plans and avoid scheduling conflicts.
● Space reservation
● Reserve rack space for new equipment to be
installed quickly and easily.
● Asset audit trail
● Track asset moves, adds and changes by
date/time, owner and work orders for view, print
and export.
● New! Customizable templates
● Specify the activities required to fulfill the needs
of the individual work order, ensuring
organizational policies and projects are easily
applied to moves, adds and changes.
Fully integrated workflow management for your IT physical
infrastructure
● New! IT power and utilization
monitoring
● Determine the business usefulness for all
IT assets helps eliminate underutilized
servers and maximize IT capacity at the
rack, row and room level.
● New! Track underutilized servers
● Reduce costs by eliminating unnecessary
servers and maximize efficiency and rack
capacity.
● New! Server usage chargeback
● Enables businesses to capture and assign
IT costs to individual departments for
accurate billing support down to the
physical or virtual server level.
DATA CENTER OPERATION:
IT OPTIMIZE
● New! IT asset auto-discovery
● Saves time and increases accuracy of your
managed asset inventory.
● New! Auto-association
● Shows Increases accuracy and saves time by
auto-associating discovered IT devices with the
inventory, based on properties such as make,
model and IP address.
● New! GenomeTM library
● The continuously growing asset library enables
the software to determine power consumption
without the aid of hardware sensors.
Reduce IT system energy usage through in-depth optimization of
server utilization for increased data center performance
● Energy efficiency analysis
● Provides current and historical PUE/DCiE
values based on the current IT-load for a
fact-based understanding of energy
efficiency at the facility level.
● Subsystem energy losses
● Provides insight into energy losses and
cost of energy at subsystem level,
providing details of which subsystem draws
the most costs.
● No measured data required
● Utilizes measured or modeled data,
allowing for usage with few or no power
meters.
● Multi-vendor data integration
● Enables integration with 3rd party enterprise and
building management systems, such as TAC Vista,
for data gathering and customisation, and
integration of PUE/DCiE calculations.
● Web-enabled interface
● Created for easy integration with 3rd party web
page through an open platform.
● PUE/DCiE report
● Provides a report on current and historical
PUE/DCiE values, showing the effect of changing
seasons, suitable for both internal and external
display.
Intelligent PUE/DCiE analytics at subsystem level
Data Center Operation:
Energy Efficiency
● Energy charge back
● Shows the cost of energy consumption for
specified equipment on room and customer
level, for aiding charge back.
● Energy usage report
● Enables accurate cost analysis of energy
use on a kW/h basis, detailed to the rack
level.
● Calculations based on PUE
● Includes an overhead factor or Power
Usage Effectiveness (PUE) for calculating
actual energy usage.
● Measured or nameplate data
● The report is based on measured data if available,
otherwise adjusted nameplate values.
● Export of reports
● Customized reports can easily be shared with all
stakeholders through support of various file
formats (html, csv, excel and pdf).
● Adapt to local costs
● Provides the option of calculating energy usage
based on local costs and currency.
Instant overview of rack energy usage
Data Center Operation:
Energy Cost
● Custom reporting tool
● Advanced report designer that allows you to
design any report within minutes using drag
and drop functionalities.
● Large set of templates
● Choose between a large selection of report
templates, or design your own customized
report and save it for future use.
● Report building with external data points
● Allows building of reports that combine
StruxureWare Operation data with any external
data points obtainable via web services or
databases.
● Reporting capabilities
● Transparency of key performance
indicators in your data center.
● Export of reports
● Customized reports can easily be shared
with all stakeholders through support of
various file formats (html, csv, excel and
pdf).
● Open platform
● Supported by a large op source community
through its Eclipse BIRT origin, Operation
Insight has access to increasing numbers
of online templates, plugins, tutorials and
stylesheets.
Comprehensive tool for customizing report designs to visualize data
Data Center Operation: Insight
DATA CENTER OPERATION:
DASHBOARD
• Easy configuration
• Built on an open platform, the user-friendly
interface allows for to quickly configure a
dashboard showing management-level
information.
• Publish to intranet & www
• The widgets displaying data center metrics
can easily be re-used on the customer’s
intranet or website.
• Open platform
•Allows for easy compilation of web
dashboards that combine StruxureWare
Operation data with other data center metrics.
Instant transparency to data center key performance indicators
• Reporting capabilities
• Provides customized CEO-level view of data
center operations for instant overview of key
metrics.
• Web dashboard
•Easy-configurable web dashboards showing
data center key performance indicators, such
as trending of data center parameters and
capacity utilization.
• Match designs
• Easy configuration with simple drag and
drop functionalities that opens up for
modifications to match the customer’s theme
and design.
DATA CENTER OPERATION:
VIZOR
• Graphical overview
● Graphical overview of power,
cooling, space, and network on a
weekly, monthly, or yearly basis.
● Barcode scan functionality
● Barcode scanning option for easy
identification of assets
● Remaining capacity calculation
● Drill down view into any location or
room and predictions of remaining
capacity based on growth rate.
● Capacity chart
● High level values of data center
utilization at a glance
● KPI Overview
● Shows key performance
indicators on power,
cooling, space, and network
within the data center
View high level values of data center utilization on your smart phone or tablet
Structure Ware Operation VIZOR
is currently available on Apple
iPhone, iPad, and Android based
devices.
DATA CENTER OPERATION: MOBILE
● Mobile work orders
● View work orders and immediately update status
as you complete tasks
● Mobile barcode asset search
● Quickly locate bar-coded assets via the search
functionality using the optional StruxureWare
Operation Mobile
● Rack audit
● Perform instant inventory management through
view of rack content and history
● Offline mobile synchronization
● Keep your physical data center synchronized
with your StruxureWare Operation Mobile
● Mobile alarms
● Provides alarms, alarm descriptions and
recommended actions for data center operations
on the go
● Wireless mobile access
● Work online or offline to access work orders and
asset data whilst on the move
● Mobile device moves
● Eliminate manual data entry and reduce errors
by adding, moving & retiring devices
Wireless operation of your data center
● Multi-vendor monitoring
● Monitor any device on the network from any
manufacturer
● Real-time device monitoring
● Immediate fault notification and real-time data for
modelling, reporting and analysis
● Intelligent alerting
● Minimise response time with pre-set or
customizable alerts so the right alert goes to the
right person at the right time
● Copy and paste alerting preferences from one set
of devices to another
● Centralised view
● Centralised data repository and unified view from
anywhere on the network
End to end data centre monitoring and control of power, cooling, environment
and security from the building through IT systems
● Auto-discovery
● Reduce the time needed to install & deploy
physical infrastructure devices by automatically
detecting manageable devices on your network
● Mass configuration
● Create, save & push configurations & device
settings to APC devices with a NMC
● Graphical trending analysis
● Access current, historic and future trends for
any device or group of devices. Plot and graph
multiple data points in a logical correlation to
visualise potential hazardous trends
STRUCTURE WARE DATA CENTER EXPERT
STRUCTURE WARE FOR DATA CENTERS
SERVICES
Implementing the StruxureWare for Data Centers Services
Software
Installation
Installation and registration of
your newly purchased Schneider
Electric Management product in
accordance to manufacturer
specification fulfilled by highly
skilled field service engineers.
Software
Configuration
Ensuring most value for your
new investment in an Schneider
Electric Management product by
quickly and precisely configuring
the system to suit your specific
business needs while utilising
the full capabilities of the
product.
Software
Enhancement
Not all computing
environments are the
same. Customise our
products by working
directly with ours senior
software engineers turning
products into "solutions"
within your new or existing
computing environment.
Software Integration
Provide planning, design and
project management for the
integration of an Schneider
Electric Management product
into your existing software or
system.
Software Maintenance
Make sure your investment
says current. Our software
support services provide in
depth technical support and
software updates making sure
your products stay current.
Software Education
Get the most from your
investment by learning
operational skills and best
practices. Our professional
trainers will teach your staff
on location.
SOLUTION BENEFITS
Real-time data embedded in intelligent data center model
Leading DCIM platform recognized by the analyst community
Patented 3D cooling technology for locating hot spots and
identifying excessive cooling
Uniquely integrated with virtualization management ensuring high
availability
Certified field service engineers ensure worry-free implementation
for your attention

More Related Content

What's hot

Simplifying Data Center Design/ Build
Simplifying Data Center Design/ BuildSimplifying Data Center Design/ Build
Simplifying Data Center Design/ BuildSchneider Electric
 
Datacenter101
Datacenter101Datacenter101
Datacenter101tarundua
 
Designing and Building a Tier 4, 20 MW Datacenter
Designing and Building a Tier 4, 20 MW DatacenterDesigning and Building a Tier 4, 20 MW Datacenter
Designing and Building a Tier 4, 20 MW DatacenterChristopher Kelley
 
POWER POINT PRESENTATION ON DATA CENTER
POWER POINT PRESENTATION ON DATA CENTERPOWER POINT PRESENTATION ON DATA CENTER
POWER POINT PRESENTATION ON DATA CENTERvivekprajapatiankur
 
The Data Center Evolution and Pre-Fab Data Centers
The Data Center Evolution and Pre-Fab Data CentersThe Data Center Evolution and Pre-Fab Data Centers
The Data Center Evolution and Pre-Fab Data CentersSchneider Electric
 
Data Center Floor Design - Your Layout Can Save of Kill Your PUE & Cooling Ef...
Data Center Floor Design - Your Layout Can Save of Kill Your PUE & Cooling Ef...Data Center Floor Design - Your Layout Can Save of Kill Your PUE & Cooling Ef...
Data Center Floor Design - Your Layout Can Save of Kill Your PUE & Cooling Ef...Maria Demitras
 
Importance of data centers
Importance of data centersImportance of data centers
Importance of data centersTyrone Systems
 
Datacenter best practices design and implementation
Datacenter best practices design and implementationDatacenter best practices design and implementation
Datacenter best practices design and implementationAnton An
 
Data center design 2
Data center design 2Data center design 2
Data center design 2Aditya Gupta
 
Data center architecture
Data center architecture Data center architecture
Data center architecture RajuPrasad33
 
Data Center 101: What to Look for in a Colocation Provider
Data Center 101: What to Look for in a Colocation ProviderData Center 101: What to Look for in a Colocation Provider
Data Center 101: What to Look for in a Colocation ProviderHostway|HOSTING
 
Craft an End-to-End Data Center Consolidation Strategy to Maximize Benefits
Craft an End-to-End Data Center Consolidation Strategy to Maximize BenefitsCraft an End-to-End Data Center Consolidation Strategy to Maximize Benefits
Craft an End-to-End Data Center Consolidation Strategy to Maximize BenefitsInfo-Tech Research Group
 
Tia 942 Data Center Standards
Tia 942 Data Center StandardsTia 942 Data Center Standards
Tia 942 Data Center StandardsSri Chalasani
 

What's hot (20)

Simplifying Data Center Design/ Build
Simplifying Data Center Design/ BuildSimplifying Data Center Design/ Build
Simplifying Data Center Design/ Build
 
Datacenter101
Datacenter101Datacenter101
Datacenter101
 
Designing and Building a Tier 4, 20 MW Datacenter
Designing and Building a Tier 4, 20 MW DatacenterDesigning and Building a Tier 4, 20 MW Datacenter
Designing and Building a Tier 4, 20 MW Datacenter
 
POWER POINT PRESENTATION ON DATA CENTER
POWER POINT PRESENTATION ON DATA CENTERPOWER POINT PRESENTATION ON DATA CENTER
POWER POINT PRESENTATION ON DATA CENTER
 
Modular Data Center Design
Modular Data Center DesignModular Data Center Design
Modular Data Center Design
 
Best Practices for Planning your Datacenter
Best Practices for Planning your DatacenterBest Practices for Planning your Datacenter
Best Practices for Planning your Datacenter
 
The Data Center Evolution and Pre-Fab Data Centers
The Data Center Evolution and Pre-Fab Data CentersThe Data Center Evolution and Pre-Fab Data Centers
The Data Center Evolution and Pre-Fab Data Centers
 
DCIM
DCIMDCIM
DCIM
 
Data Center Floor Design - Your Layout Can Save of Kill Your PUE & Cooling Ef...
Data Center Floor Design - Your Layout Can Save of Kill Your PUE & Cooling Ef...Data Center Floor Design - Your Layout Can Save of Kill Your PUE & Cooling Ef...
Data Center Floor Design - Your Layout Can Save of Kill Your PUE & Cooling Ef...
 
DATA CENTER
DATA CENTER DATA CENTER
DATA CENTER
 
Data center
Data centerData center
Data center
 
Data Center
Data CenterData Center
Data Center
 
Importance of data centers
Importance of data centersImportance of data centers
Importance of data centers
 
Datacenter best practices design and implementation
Datacenter best practices design and implementationDatacenter best practices design and implementation
Datacenter best practices design and implementation
 
Data center design 2
Data center design 2Data center design 2
Data center design 2
 
Data center architecture
Data center architecture Data center architecture
Data center architecture
 
Data Center 101: What to Look for in a Colocation Provider
Data Center 101: What to Look for in a Colocation ProviderData Center 101: What to Look for in a Colocation Provider
Data Center 101: What to Look for in a Colocation Provider
 
Data centerefficiency
Data centerefficiencyData centerefficiency
Data centerefficiency
 
Craft an End-to-End Data Center Consolidation Strategy to Maximize Benefits
Craft an End-to-End Data Center Consolidation Strategy to Maximize BenefitsCraft an End-to-End Data Center Consolidation Strategy to Maximize Benefits
Craft an End-to-End Data Center Consolidation Strategy to Maximize Benefits
 
Tia 942 Data Center Standards
Tia 942 Data Center StandardsTia 942 Data Center Standards
Tia 942 Data Center Standards
 

Similar to Data Center Infrastructure Management(DCIM)

Schneider - ASK THE EXPERT - ITNEXT
Schneider - ASK THE EXPERT - ITNEXTSchneider - ASK THE EXPERT - ITNEXT
Schneider - ASK THE EXPERT - ITNEXTAniket Patange
 
A More Efficient Way to Automate Cloud Infrastructure Solution Profile
A More Efficient Way to Automate Cloud Infrastructure Solution ProfileA More Efficient Way to Automate Cloud Infrastructure Solution Profile
A More Efficient Way to Automate Cloud Infrastructure Solution ProfileHitachi Vantara
 
Smart Manufacturing Suite for Power Industry
Smart Manufacturing Suite for Power IndustrySmart Manufacturing Suite for Power Industry
Smart Manufacturing Suite for Power IndustryA.T.E. Private Limited
 
Cloud Capacity Management
Cloud Capacity ManagementCloud Capacity Management
Cloud Capacity ManagementPrecisely
 
Visualizing Your Network Health - Know your Network
Visualizing Your Network Health - Know your NetworkVisualizing Your Network Health - Know your Network
Visualizing Your Network Health - Know your NetworkDellNMS
 
Data Center Infrastructure Management
Data Center Infrastructure ManagementData Center Infrastructure Management
Data Center Infrastructure Managementshahzad ahmed
 
Introducing Elevate Capacity Management
Introducing Elevate Capacity ManagementIntroducing Elevate Capacity Management
Introducing Elevate Capacity ManagementPrecisely
 
Systemology presentation- System Center & the modern datacenter
Systemology presentation- System Center & the modern datacenterSystemology presentation- System Center & the modern datacenter
Systemology presentation- System Center & the modern datacenterjmustac
 
The Software-Defined Data Center and it’s impact on the physical infrastruc...
The Software-Defined Data  Center and it’s impact on the  physical infrastruc...The Software-Defined Data  Center and it’s impact on the  physical infrastruc...
The Software-Defined Data Center and it’s impact on the physical infrastruc...Schneider Electric
 
Data Centre Overview
Data Centre OverviewData Centre Overview
Data Centre OverviewLogicalis
 
Logicalis - Data Centre Overview
Logicalis - Data Centre OverviewLogicalis - Data Centre Overview
Logicalis - Data Centre OverviewLogicalis
 
Data Center Monitoring and Management Best Practices: How You Can Benefit fro...
Data Center Monitoring and Management Best Practices: How You Can Benefit fro...Data Center Monitoring and Management Best Practices: How You Can Benefit fro...
Data Center Monitoring and Management Best Practices: How You Can Benefit fro...Upsite Technologies
 
Improving Datacenter Performance through Capacity Planning – Netmagic
Improving Datacenter Performance through Capacity Planning – NetmagicImproving Datacenter Performance through Capacity Planning – Netmagic
Improving Datacenter Performance through Capacity Planning – NetmagicNetmagic Solutions Pvt. Ltd.
 
Data Center Infrastructure Management Demystified
Data Center Infrastructure Management Demystified Data Center Infrastructure Management Demystified
Data Center Infrastructure Management Demystified Sunbird DCIM
 
Trellis DCIM Platform
Trellis DCIM PlatformTrellis DCIM Platform
Trellis DCIM PlatformGreg Stover
 
Visualizing Your Network Health - Driving Visibility in Increasingly Complex...
Visualizing Your Network Health -  Driving Visibility in Increasingly Complex...Visualizing Your Network Health -  Driving Visibility in Increasingly Complex...
Visualizing Your Network Health - Driving Visibility in Increasingly Complex...DellNMS
 
Future Facilities 6SigmaDCX Overview HD
Future Facilities 6SigmaDCX Overview HDFuture Facilities 6SigmaDCX Overview HD
Future Facilities 6SigmaDCX Overview HDRobert Schmidt
 

Similar to Data Center Infrastructure Management(DCIM) (20)

Schneider - ASK THE EXPERT - ITNEXT
Schneider - ASK THE EXPERT - ITNEXTSchneider - ASK THE EXPERT - ITNEXT
Schneider - ASK THE EXPERT - ITNEXT
 
A More Efficient Way to Automate Cloud Infrastructure Solution Profile
A More Efficient Way to Automate Cloud Infrastructure Solution ProfileA More Efficient Way to Automate Cloud Infrastructure Solution Profile
A More Efficient Way to Automate Cloud Infrastructure Solution Profile
 
Apc - 8dec2010
Apc - 8dec2010Apc - 8dec2010
Apc - 8dec2010
 
Smart Manufacturing Suite for Power Industry
Smart Manufacturing Suite for Power IndustrySmart Manufacturing Suite for Power Industry
Smart Manufacturing Suite for Power Industry
 
Cloud Capacity Management
Cloud Capacity ManagementCloud Capacity Management
Cloud Capacity Management
 
Visualizing Your Network Health - Know your Network
Visualizing Your Network Health - Know your NetworkVisualizing Your Network Health - Know your Network
Visualizing Your Network Health - Know your Network
 
DCIM: ERP for the Data Center Manager
DCIM: ERP for the Data Center ManagerDCIM: ERP for the Data Center Manager
DCIM: ERP for the Data Center Manager
 
Data Center Infrastructure Management
Data Center Infrastructure ManagementData Center Infrastructure Management
Data Center Infrastructure Management
 
Introducing Elevate Capacity Management
Introducing Elevate Capacity ManagementIntroducing Elevate Capacity Management
Introducing Elevate Capacity Management
 
Systemology presentation- System Center & the modern datacenter
Systemology presentation- System Center & the modern datacenterSystemology presentation- System Center & the modern datacenter
Systemology presentation- System Center & the modern datacenter
 
The Software-Defined Data Center and it’s impact on the physical infrastruc...
The Software-Defined Data  Center and it’s impact on the  physical infrastruc...The Software-Defined Data  Center and it’s impact on the  physical infrastruc...
The Software-Defined Data Center and it’s impact on the physical infrastruc...
 
Data Centre Overview
Data Centre OverviewData Centre Overview
Data Centre Overview
 
Logicalis - Data Centre Overview
Logicalis - Data Centre OverviewLogicalis - Data Centre Overview
Logicalis - Data Centre Overview
 
Data Center Monitoring and Management Best Practices: How You Can Benefit fro...
Data Center Monitoring and Management Best Practices: How You Can Benefit fro...Data Center Monitoring and Management Best Practices: How You Can Benefit fro...
Data Center Monitoring and Management Best Practices: How You Can Benefit fro...
 
Improving Datacenter Performance through Capacity Planning – Netmagic
Improving Datacenter Performance through Capacity Planning – NetmagicImproving Datacenter Performance through Capacity Planning – Netmagic
Improving Datacenter Performance through Capacity Planning – Netmagic
 
StruxureWare DCIM Q&A
StruxureWare DCIM Q&AStruxureWare DCIM Q&A
StruxureWare DCIM Q&A
 
Data Center Infrastructure Management Demystified
Data Center Infrastructure Management Demystified Data Center Infrastructure Management Demystified
Data Center Infrastructure Management Demystified
 
Trellis DCIM Platform
Trellis DCIM PlatformTrellis DCIM Platform
Trellis DCIM Platform
 
Visualizing Your Network Health - Driving Visibility in Increasingly Complex...
Visualizing Your Network Health -  Driving Visibility in Increasingly Complex...Visualizing Your Network Health -  Driving Visibility in Increasingly Complex...
Visualizing Your Network Health - Driving Visibility in Increasingly Complex...
 
Future Facilities 6SigmaDCX Overview HD
Future Facilities 6SigmaDCX Overview HDFuture Facilities 6SigmaDCX Overview HD
Future Facilities 6SigmaDCX Overview HD
 

Data Center Infrastructure Management(DCIM)

  • 2. DATA CENTER MANAGEMENT CHALLENGES Data Center Availability Business Efficiency Balance the demands of availability and efficiency through out the data center lifecycle
  • 3. IN AN ENVIRONMENT OF CONSTANT CHANGE Energy and service cost control Increasing availability expectations Regulatory requirements Dynamic power variation Uncertain planning for capacity or density Cloud computing Energy efficiency Virtualization Metrics and reporting Server consolidation Infrastructure management Data center managers need accurate and timely information to make better decisions in real time
  • 4. DCIM MARKET DEFINITION Data center infrastructure management (DCIM) systems collect and manage data about a data center’s assets, resource use and operational status throughout the data center lifecycle. This information is then distributed, integrated, analyzed and applied in ways that help managers meet business and service- oriented goals and optimize the data center’s performance Physical Functional Process • Power system • Cooling system • IT space • Security • integrations • Monitoring and alarming • Automation and control • Modeling and simulation • Software Services, • Integrations • Asset management • Availability management • Capacity management • Change management • Crisis management • Financial management, • Integrations
  • 5. Level 5: Self optimizing, autonomic Multiple IT and infrastructure subsystems integrated; data models used for prediction, service management, multiple views, optimizing in near real time. 0% DCIM MATURITY MODEL Level 4: Optimizing Multiple IT and infrastructure subsystems integrated; data models used for prediction, service management, multiple views, optimizing in near real time. 5% Level 3: Proactive Datacenter equipment characteristics, location and operational status tracked. Energy and environmental data used to reduce risks, waste. 30% Level 2: Reactive Software installed to monitor environment and equipment power use. Ability to adjust cooling to demand. 80% Level 1: Basic No integration; basic monitoring supplied with equipment. Health and safety. 95%
  • 6. Utility Building Data Center Infrastructure IT hardware Hypervisor Virtual Machines Business Value Applications Virtualization Management Data Center Infrastructure Management (DCIM) DEMAND SUPPLY DEMAND SUPPLY
  • 7. SCHNEIDER ELECTRIC’S DCIM SOLUTIONS A suite of modular and integrated DCIM software tools that enable effective data center management Resource Advisor Data Center Operation Data Center Expert Power Monitoring Expert Building Operation
  • 8. STRUCTURE FOR DATA CENTERS Component Benefit Resource Advisor Data Center Operation Data Center Expert Power Monitoring Expert Enterprise Energy and Sustainability Data Center Business Process Data Center Monitoring and Control Track and manage enterprise energy and carbon costs Manage Data Center assets, operational and capital costs Monitor and control Data Center power, cooling and security Advanced power monitoring, analysis and power quality Advanced cooling monitoring and automation Building Operation
  • 9. EXPECTED MARKED GROWTH (1) “Overall, The 451 Group believes that the DCIM market is worth around $240m in 2011, and will grow to $1.2bn in 2016.” ” DATACENTER INFRASTRUCTURE MANAGEMENT SOFTWARE”,
  • 10. EXPECTED MARKED GROWTH (2) “DCIM tools and processes will become mainstream in data centers, growing from 1% penetration in 2010 to 60% in 2014.”
  • 11. SCHNEIDER A LEADER IN THE DCIM MARKET “According to IDC analysis and buyer perception, Schneider Electric is an IDC MarketScape Leader worldwide.” ”IDC: Markets cape: Worldwide Datacenter Infrastructure Management (DCIM)
  • 12. BUSINESS BENEFITS It is difficult to achieve the more advanced levels of datacenter maturity, or of datacenter effectiveness generally, without extensive use of DCIM software (451 Group, 2011) Energy savings from well-managed data centers can reduce operating expenses by as much as 20% (Gartner, 2010) One integrated system bridging the gap between Facilities and IT Plug’n’Play data center key performance indicators on web and smart phone dashboards Typical solution payback is less than 12 months
  • 13. A new level of business intelligence for your Data Center Infrastructure Management (DCIM). Ability today to integrate management platforms A vision for tomorrow for simplified, integrated management Remove silos & create energy awareness across the entire data center STRUCTURE WARE DATA CENTER OPERATION PLANNING Improve IT room allocation of power & cooling ANALYSIS Leverage historical data to improve future performance in the data center OPERATIONS Rapid impact analysis in the event of failure in the data center I need to know what happens before a failure occurs IT Professional Part of Structure for Data Centers
  • 14. ● Inventory management ● Shows device data within the physical layout for instant access to device details and asset attributes, and overview of data center operations. ● Alarms within physical layout ● Provides real-time device failures within floor layout and rack front view for live status of data center operations ● PUE/ DCiE calculator ● Provides Power Usage Effectiveness (PUE) or Data Center infrastructure Efficiency (DCiE) value for information on daily utilization of energy. STRUCTURE WARE DATA CENTER OPERATION ● Network management ● An overview of the data center network paths and their interconnections, provided through guided input for reduction of human error. ● Global asset search ● Quickly locate assets through free text search and export equipment data to excel format ● Mobile data center operations ● Integrates with Operation Mobile for access to StruxureWare Operation on the go via the Motorola MC75 handheld PDA. ● Live dashboard ● Gain transparency to data center key performance indicators through easily configured web dashboards, displaying customizable management-level information Asset management and documentation of data center operations through inventory management
  • 15. THE MODULAR SETUP Structure Ware Data Center Operation forms the base layer of software, which other modules and enhancement options can be added onto. StruxureWare Data Center Operation StruxureWare Data Center Expert Structure Ware Data Center Expert is the preferred data center monitoring platform for the solution. Integrations BMC Remedy Microsoft VMM Microsoft SCOM Vmware vSphere Cisco UCS Microsoft Excel Aperture Schneider Electric StruxureWare Data Center Operation StruxureWare Data Center Expert HP Openview
  • 16. ● IT equipment guidance ● Instant server placement recommendation through real-time analysis of available data center capacity. ● Virtualization capabilities ● Integrations with VMware vSphere and Microsoft System Center Virtual Machine Manager ● Combines information from the IT layer and the physical infrastructure layer, enabling data center managers to automatically migrate their impacted virtual machines from an impacted host server to a healthy host server. DATA CENTER OPERATION: CAPACITY ● Available capacity ● Global view of available capacity within an organizational context, providing an instant calculation of actual space, power and cooling consumption, power and network port availability and floor and rack weight limits against overall data center capacity constraints. ● Business impact ● Shows the consequence of device failure on data center infrastructure equipment for instant identification of critical business application impacts. ● 3D airflow analysis ● Simulate any cooling scenario in your data center, instantly visualizing the cooling effect on your infrastructure for easy identification of overcooling and hotspots. Simulation, planning, and optimization of infrastructure capacities to right-size the data center
  • 17. ● Automated work order process ● Create work orders and automatically generate tasks to move, add or change IT and infrastructure equipment. ● Schedule, assign and track the status of itemized tasks to implement changes in the data center. ● New! Change management overview ● Interactive interface showing past, future and pending changes to assist with resource and workload balancing, avoiding scheduling conflicts. ● New! BMC Remedy integration ● Ensure relevant information is shared and flowing between Operation Change and the market leading process management system. DATA CENTER OPERATION: CHANGE ● New! Maintenance scheduling ● Facilitate scheduling of service and equipment maintenance to ensure visibility to all service plans and avoid scheduling conflicts. ● Space reservation ● Reserve rack space for new equipment to be installed quickly and easily. ● Asset audit trail ● Track asset moves, adds and changes by date/time, owner and work orders for view, print and export. ● New! Customizable templates ● Specify the activities required to fulfill the needs of the individual work order, ensuring organizational policies and projects are easily applied to moves, adds and changes. Fully integrated workflow management for your IT physical infrastructure
  • 18. ● New! IT power and utilization monitoring ● Determine the business usefulness for all IT assets helps eliminate underutilized servers and maximize IT capacity at the rack, row and room level. ● New! Track underutilized servers ● Reduce costs by eliminating unnecessary servers and maximize efficiency and rack capacity. ● New! Server usage chargeback ● Enables businesses to capture and assign IT costs to individual departments for accurate billing support down to the physical or virtual server level. DATA CENTER OPERATION: IT OPTIMIZE ● New! IT asset auto-discovery ● Saves time and increases accuracy of your managed asset inventory. ● New! Auto-association ● Shows Increases accuracy and saves time by auto-associating discovered IT devices with the inventory, based on properties such as make, model and IP address. ● New! GenomeTM library ● The continuously growing asset library enables the software to determine power consumption without the aid of hardware sensors. Reduce IT system energy usage through in-depth optimization of server utilization for increased data center performance
  • 19. ● Energy efficiency analysis ● Provides current and historical PUE/DCiE values based on the current IT-load for a fact-based understanding of energy efficiency at the facility level. ● Subsystem energy losses ● Provides insight into energy losses and cost of energy at subsystem level, providing details of which subsystem draws the most costs. ● No measured data required ● Utilizes measured or modeled data, allowing for usage with few or no power meters. ● Multi-vendor data integration ● Enables integration with 3rd party enterprise and building management systems, such as TAC Vista, for data gathering and customisation, and integration of PUE/DCiE calculations. ● Web-enabled interface ● Created for easy integration with 3rd party web page through an open platform. ● PUE/DCiE report ● Provides a report on current and historical PUE/DCiE values, showing the effect of changing seasons, suitable for both internal and external display. Intelligent PUE/DCiE analytics at subsystem level Data Center Operation: Energy Efficiency
  • 20. ● Energy charge back ● Shows the cost of energy consumption for specified equipment on room and customer level, for aiding charge back. ● Energy usage report ● Enables accurate cost analysis of energy use on a kW/h basis, detailed to the rack level. ● Calculations based on PUE ● Includes an overhead factor or Power Usage Effectiveness (PUE) for calculating actual energy usage. ● Measured or nameplate data ● The report is based on measured data if available, otherwise adjusted nameplate values. ● Export of reports ● Customized reports can easily be shared with all stakeholders through support of various file formats (html, csv, excel and pdf). ● Adapt to local costs ● Provides the option of calculating energy usage based on local costs and currency. Instant overview of rack energy usage Data Center Operation: Energy Cost
  • 21. ● Custom reporting tool ● Advanced report designer that allows you to design any report within minutes using drag and drop functionalities. ● Large set of templates ● Choose between a large selection of report templates, or design your own customized report and save it for future use. ● Report building with external data points ● Allows building of reports that combine StruxureWare Operation data with any external data points obtainable via web services or databases. ● Reporting capabilities ● Transparency of key performance indicators in your data center. ● Export of reports ● Customized reports can easily be shared with all stakeholders through support of various file formats (html, csv, excel and pdf). ● Open platform ● Supported by a large op source community through its Eclipse BIRT origin, Operation Insight has access to increasing numbers of online templates, plugins, tutorials and stylesheets. Comprehensive tool for customizing report designs to visualize data Data Center Operation: Insight
  • 22. DATA CENTER OPERATION: DASHBOARD • Easy configuration • Built on an open platform, the user-friendly interface allows for to quickly configure a dashboard showing management-level information. • Publish to intranet & www • The widgets displaying data center metrics can easily be re-used on the customer’s intranet or website. • Open platform •Allows for easy compilation of web dashboards that combine StruxureWare Operation data with other data center metrics. Instant transparency to data center key performance indicators • Reporting capabilities • Provides customized CEO-level view of data center operations for instant overview of key metrics. • Web dashboard •Easy-configurable web dashboards showing data center key performance indicators, such as trending of data center parameters and capacity utilization. • Match designs • Easy configuration with simple drag and drop functionalities that opens up for modifications to match the customer’s theme and design.
  • 23. DATA CENTER OPERATION: VIZOR • Graphical overview ● Graphical overview of power, cooling, space, and network on a weekly, monthly, or yearly basis. ● Barcode scan functionality ● Barcode scanning option for easy identification of assets ● Remaining capacity calculation ● Drill down view into any location or room and predictions of remaining capacity based on growth rate. ● Capacity chart ● High level values of data center utilization at a glance ● KPI Overview ● Shows key performance indicators on power, cooling, space, and network within the data center View high level values of data center utilization on your smart phone or tablet Structure Ware Operation VIZOR is currently available on Apple iPhone, iPad, and Android based devices.
  • 24. DATA CENTER OPERATION: MOBILE ● Mobile work orders ● View work orders and immediately update status as you complete tasks ● Mobile barcode asset search ● Quickly locate bar-coded assets via the search functionality using the optional StruxureWare Operation Mobile ● Rack audit ● Perform instant inventory management through view of rack content and history ● Offline mobile synchronization ● Keep your physical data center synchronized with your StruxureWare Operation Mobile ● Mobile alarms ● Provides alarms, alarm descriptions and recommended actions for data center operations on the go ● Wireless mobile access ● Work online or offline to access work orders and asset data whilst on the move ● Mobile device moves ● Eliminate manual data entry and reduce errors by adding, moving & retiring devices Wireless operation of your data center
  • 25. ● Multi-vendor monitoring ● Monitor any device on the network from any manufacturer ● Real-time device monitoring ● Immediate fault notification and real-time data for modelling, reporting and analysis ● Intelligent alerting ● Minimise response time with pre-set or customizable alerts so the right alert goes to the right person at the right time ● Copy and paste alerting preferences from one set of devices to another ● Centralised view ● Centralised data repository and unified view from anywhere on the network End to end data centre monitoring and control of power, cooling, environment and security from the building through IT systems ● Auto-discovery ● Reduce the time needed to install & deploy physical infrastructure devices by automatically detecting manageable devices on your network ● Mass configuration ● Create, save & push configurations & device settings to APC devices with a NMC ● Graphical trending analysis ● Access current, historic and future trends for any device or group of devices. Plot and graph multiple data points in a logical correlation to visualise potential hazardous trends STRUCTURE WARE DATA CENTER EXPERT
  • 26. STRUCTURE WARE FOR DATA CENTERS SERVICES Implementing the StruxureWare for Data Centers Services Software Installation Installation and registration of your newly purchased Schneider Electric Management product in accordance to manufacturer specification fulfilled by highly skilled field service engineers. Software Configuration Ensuring most value for your new investment in an Schneider Electric Management product by quickly and precisely configuring the system to suit your specific business needs while utilising the full capabilities of the product. Software Enhancement Not all computing environments are the same. Customise our products by working directly with ours senior software engineers turning products into "solutions" within your new or existing computing environment. Software Integration Provide planning, design and project management for the integration of an Schneider Electric Management product into your existing software or system. Software Maintenance Make sure your investment says current. Our software support services provide in depth technical support and software updates making sure your products stay current. Software Education Get the most from your investment by learning operational skills and best practices. Our professional trainers will teach your staff on location.
  • 27. SOLUTION BENEFITS Real-time data embedded in intelligent data center model Leading DCIM platform recognized by the analyst community Patented 3D cooling technology for locating hot spots and identifying excessive cooling Uniquely integrated with virtualization management ensuring high availability Certified field service engineers ensure worry-free implementation